Durocell 111 - ECO line

  • Highly durable laboratory oven
  • 111-liter chamber volume
  • Working temperature of from +5°C over ambient temperature up to 125°C
  • Natural fine air flow in the chamber, noiseless operation
  • High-quality and safe drying, heating and tempering of laboratory materials in laboratories and industry; perfect anticorrosive protection of all chamber parts (protective Epolon plastic) enabling wirk with acids and dases, acid and alkaline hydrolysis etc.
  • High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening
  • Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display
  • Wide range of optional equipment and accessories
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)



Technical data

Interior of stainless steel material No. 1.4301

  • volume 111 l
  • depth 390 mm
  • width 540 mm
  • height 530 mm

Trays

  • standard equipment 2 pcs
  • storage area (w × d) 520×335 mm
  • racks 7 max. no
  • distance between guide rails 70 mm

Maximal weight of the load*)

  • inside the oven 50 kg/oven
  • per tray 20 kg/tray

Door

  • 1 pcs

External dimensions (including door and handle)

  • depth 640 mm
  • diameter of the air branch outer/inner 52/49 mm
  • width 830 mm
  • height (inclusive foots - N) 860 (N) mm

Package dimensions (three layers carton)

  • depth 730 mm
  • width 830 mm
  • depth 1060 mm

Weight

  • brut 87 kg
  • nett 75 kg

Working temperature (beginning of the regulation)

  • from 5 °C above ambient temp. to: 125 °C

Temperature accuracy according to DIN 12 880 T2, at working temperature with closed air flap and door

  • time variation cca (±) 0,8 °C
  • space deviation cca (±) % of the reached temperature 2 %

Time required to reach 100 °C with closed air flap and voltage 230 V

  • 48 min

Heat emission at 100 °C

  • 490 W

Air exchange speed at 100 °C

  • 12 per hour

Electricity – mains 50/60 Hz

  • max. power input 1,8 kW
  • nominal voltage 230 V
  • current 7,8 A
  • input in stand by mode 5 W

Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.

Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters.

Contact form

Are you interesting in our offer? Please fill the contact form, we will be pleased to contact you.

Interest in:

Based on the cross marking I hereby express my consent for my data to be collected and saved with the purpose of my inquiry processing. Such consent may be cancelled at any time by sending a message for our attention. You can get detailed information from the Declaration of Data Protection. *

* Required