Ecocell 22 - ECO line

  • Convincingly cost saving laboratory dryer
  • 22-liter chamber volume
  • Working temperature of from +5°C over ambient temperature up to 250/300°C
  • Natural fine air flow in the chamber, noiseless operation
  • High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry
  • High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening
  • Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display
  • Wide range of optional equipment and accessories
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)



Technical data

Interior of stainless steel material No. 1.4301

  • volume 22 l
  • depth 350 mm
  • width 240 mm
  • height 300 mm

Tray

  • standard equipment 2 pcs
  • storage area (w × d) 185×265 mm
  • racks 4 max. no
  • distance between guide rails 60 mm

Maximal weight of the load *)

  • inside the oven 25 kg/oven
  • per tray 10 kg/tray

Door

  • 1 pcs

External dimensions (including door and handle)

  • depth 560 mm
  • diameter of the air branch outer/inner 52/49 mm
  • width 406 mm
  • height, incl. Feet (N) and Rolls (K) 610 (N)

Package dimensions (three layers carton)

  • depth 720 mm
  • width 500 mm
  • depth 810 mm

Weight

  • brut 36 kg
  • nett 31 kg

Working temperature (beginning of the regulation)

  • from 5 °C above ambient temp. to: 250 °C

Temperature accuracy according to DIN 12 880 T2, at working temperature with closed air flap and door

  • time variation cca (±) 1 °C
  • space deviation cca (±) % of the reached temperature 2,7 %

Time required to reach 250 °C with closed air flap and voltage 230 V

  • 54 min

Heat emission at 250 °C

  • 300 W

Air exchange speed at 150 °C

  • 6 per hour

Electricity - mains 50/60 Hz

  • max. power input 0,9 kW
  • nominal voltage 230 V
  • current 4 A
  • input in stand by mode 5 W

Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.

Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters.

Contact form

Are you interesting in our offer? Please fill the contact form, we will be pleased to contact you.

Interest in:

Based on the cross marking I hereby express my consent for my data to be collected and saved with the purpose of my inquiry processing. Such consent may be cancelled at any time by sending a message for our attention. You can get detailed information from the Declaration of Data Protection. *

* Required