INCUCELL 111 - ECO line

  • Natural, precise – laboratory incubator
  • 111-liter chamber volume
  • Working temperature of from +5°C above ambient up to 100°C
  • Noiseless operation and fine air flow in the chamber
  • High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening
  • High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures
  • Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display
  • Wide range of optional equipment and accessories
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)



Technical data

Interior of stainless steel material No. 1.4301

  • volume 111 l
  • depth 370 mm
  • width 540 mm
  • height 530 mm

Tray

  • standard equipment 2 pcs
  • storage area (w × d) 520×335 mm
  • racks 7 max. number
  • distance between guide rails 70 mm

Maximal weight of the load*)

  • inside the oven 50 kg/oven
  • per tray 20 kg/tray

Door

  • 1 pcs

External dimensions (including door and handle)

  • depth 640 mm
  • diameter of the air branch outer / inner 52/49 mm
  • width 760 mm
  • height, incl. Feet (N) and Rolls (K) 860 (N)

Package dimensions (three layers carton)

  • depth 730 mm
  • width 830 mm
  • depth 1060 mm

Weight

  • brut 87 kg
  • nett 75 kg

Working temperature (beginning of the regulation)

  • from 5 °C above ambient temp. to: 100 °C

Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door

  • time variation cca (±) <=0,2 °C
  • space deviation cca (±) < 0,5 °C

Time required to reach 37 °C with closed air flap and voltage 230 V

  • 57 min

Heat emission at 37 °C

  • 45 W

Air exchange speed at 37 °C

  • 5 per hour

Electricity - mains 50/60 Hz

  • max. power 0,3 kW
  • nominal voltage 230 V
  • current 1,3 A
  • power by stand by 5 W

*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C ambient temperature and +-10 % voltage swing (if not specified).

Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters.

Contact form

Are you interesting in our offer? Please fill the contact form, we will be pleased to contact you.

Interest in:

Based on the cross marking I hereby express my consent for my data to be collected and saved with the purpose of my inquiry processing. Such consent may be cancelled at any time by sending a message for our attention. You can get detailed information from the Declaration of Data Protection. *

* Required