STERICELL 111

  • Hot-air sterilizer - meets the criteria of a medical device
  • 111-liter chamber volume
  • Working temperature of from +10°C over ambient temperature up to 250°C
  • Noiseless operation with a fine patented system of forced air flow in the chamber thanks to a built-in fan eliminating “cold air“ area formation
  • High operation comfort; precise temperature and time regulation; three preset sterilization programs
  • Suitable for hot-air sterilization at health centers for laboratory purposes; potential use as an oven
  • Model with a Fuzzy logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display
  • Wide range of optional equipment and accessories
  • Output for a printer or PC connection
  • Validation possibility (IQ , OQ)


Technical data

Interior of stainless steel material No. 1.4301

  • volume 111 l
  • depth 390 mm
  • width 540 mm
  • height 530 mm

Tray

  • standard equipment 2 pcs
  • storage area (w × d) 520×335 mm
  • racks 7 max. number
  • distance between guide rails 70 mm

Maximal weight of the load *)

  • inside the oven 50 kg/oven
  • per tray 20 kg/tray

Number of doors

  • 1 pcs

External dimensions (including door and handle)

  • depth 640 mm
  • diameter of the air branch outer/inner 52/49 mm
  • width 760 mm
  • height, incl. Feet (N) and Caster (K) 860 (N)

Package dimensions (three layers carton)

  • depth 730 mm
  • width 830 mm
  • depth 1050 mm

Weight

  • gbrut 87 kg
  • nett 75 kg

Working temperature (beginning of the regulation)

  • from 10 °C above ambient temp. to °C 250 °C

Heat emission at 250 °C

  • 760 W

Air exchange speed at 250 °C

  • 49 cca/hour

Electricity - mains 50/60 Hz

  • max. power 1,9 kW
  • nominal voltage 230 V
  • current 8,3 A
  • stand by 5 W

*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.
Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing rate ventilator 100 %, defrost off, lighting off.

Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters.

Contact form

Are you interesting in our offer? Please fill the contact form, we will be pleased to contact you.

Interest in:

Based on the cross marking I hereby express my consent for my data to be collected and saved with the purpose of my inquiry processing. Such consent may be cancelled at any time by sending a message for our attention. You can get detailed information from the Declaration of Data Protection. *

* Required